Mineral Insulated 750V Cable

Type:

Voltage: 750V

Features: A 750V heavy duty mineral insulated cable, designed to give the ultimate Fire Performance.

Application: Suitable for Oil, Gas and Petroleum industries, airports, emergency lighting systems and fire alarm systems for power and control circuits providing circuit integrity to 950°C.

Product introduction

Sunwin Cables' mineral insulated copper cables (MICC), also know as pyro cables, deliver the ultimate operating performance under fire conditions and provide circuit integrity to safety critical applications such as emergency lighting and fire alarm systems in temperatures of up to 950oC, a temperature which tends to exceed that recorded in most fires.
Type Cu、Al Specifications Core NO. Voltage
補充說明: MI cables, MIC, Pyro cable, Copper clad cable, MIMS, Magnesium oxide cable, Mineral insulated metal sheathed cable.

Type description exampl

Type exampl

For Example:
Conductor Solid plain copper (Cu) conductor
Insulation Magnesium oxide
Sheath - bare copper variant Plain copper (Cu) tube which results in no emission in the event of a fire
Sheath - LSZH variant Plain copper tube with an outersheath made of low smoke zero halogen (LSZH) compounds

Product structure diagram

Product details

This range of LPCB-approved cables, which is sometimes simply referred to as Mineral Insulated cable or MI cable, is available for light-duty applications with a voltage rating of 500V and high-duty applications with a voltage rating of 750V. MICC are manufactured by placing copper rods inside a copper tube and filling out the remaining space with magnesium oxide insulation, an inert and inorganic material. These cables are also available with a low smoke zero halogen outersheath for improved resistance against copper corrosion of the sheath. MICC have high durability due to the mechanical and electrical properties of the materials used. They have a wide operation temperature range and they are waterproof, making them suitable for installation in some of the most challenging environments.


In addition to safety critical applications, these high temperature mineral insulated copper cables are ideally suited for specific applications, such as instrumentation for nuclear reactors as the magnesium oxide provides resistance to ionizing radiation, They are also used in industries processing or handling flammable liquids where the power or control cables would be at risk of damage in the event of a fire.

Examining report

Mineral Insulated Cables are used to provide circuit integrity for power and control circuits of critical equipment such as:

    1. ·Hospital operating rooms

    2. ·Air pressurisation system for stairwells

      ·Fire alarm systems

      ·Emergency power systems、Emergency lighting systems

      ·Sprinkler systems

    3. ·Public buildings e.g. theatres, cinemas, hotels, schools

  •  
    1. · Tunnels and mines

    2. · Temperature measurement devices; RTD's, thermocouples

      · Close to or inside industrial foundries, kilns

      · Hazardous areas where flammable gases may be present

    3. · Transport hubs - railway stations, airports etc

MI cable is the best choice for building fire safety line laying

BS 6387: Cable Fire Test

Fire Performance BS 6387 Performance Requirements for Cables Required to Maintain Circuit Integrity under Fire Conditions.This standard details the following tests to categorise cables according to their fire withstand capabilities.

  • Resistance to Fire

    The cable is tested by exposure to gas burner flames while passing a current at its rated voltage.

    Four survival categories are defined in the Performance Table below.

    • Symbol condition
    • A650°C for 3 hours
    • B750°C for 3 hours
    • C 950°C for 3 hours
    • D950°C for 20 minutes

  • Resistance to Fire with Water

    A new sample of cable is exposed to flames at 650°C for 15 minutes whilst passing a current at the rated voltage and then the spray is turned on to give exposure to both fire and water for a further 15 minutes.

    The grade results are as follows:

    • Symbolcondition
    • W650°C for 15 minutes

  • Resistance to Fire with Mechanical Shock

    The final requirement is mechanical shock damage. A fresh sample of cable is mounted on a backing panel in an S-bend and is exposed to flames whilst the backing panel is struck with a solid steel bar the same diameter as the cable under test every 30 seconds for 15 minutes.

    Whilst the cable has been exposed to temperatures as defined in the Performance Table below.

    • Symbolcondition
    • X650°C for 15 minutes
    • Y750°C for 15 minutes
    • Z950°C for 15 minutes

Beyond The Standard

Sunwin MI Cable can easily comply and withstand the most onerous categories of C, W and Z using one single Cable Sample

Product support

Related products

We carefully select, select good raw materials, to create high-quality wire and cable.
Give the user a rest assured.

亚洲AV无码AV吞精久久| 国产成人精品高清在线观看99| 免费无码av片在线观看中文| 精品无码一区二区高潮久久国产 | 97久久人人爽人人爽人人片| 国产强伦姧在线观看午夜| 久久国产精品久久国产精品| 欧美三级在线播放| 3d日本无修肉动漫在线观看| 中文字幕无码色专区| 欧美大片欧美激情性色a∨在线| 欧美xxxx黑人又粗又长| 无码人妻精品一区二区三区99不卡| 少妇高潮喷潮久久久影院| 超薄丝袜足j一区二区三区| 亚洲人在线观看无码影院| 午夜寂寞成人网站在线观看| 99久久99久久久精品齐齐| 国产精品国产三级国产潘金莲| 国偷自产AV一区二区三区接| 日韩精品高清不卡一区二区三区| 国内老熟妇乱子伦视频| 免费 无码 国产在线观看九| 亚洲综合色在线观看一区二区三区| 欧美va亚洲va在线观看aa久久一级一片毛片特色| 亚洲国产成人综合精品| 无码天堂va亚洲va在线va| 久久精品国产99精品最新按摸 | 91久久精品国产成人久久| 无码av不卡一区二区三区| 婷婷色婷婷开心五月四房播播| 亚洲国产成人高清在线播放| 91久久国产综合精品女同国语| 成人午夜亚洲精品无码网站| 无码精品A在线观看十八禁| 久久久久亚洲Av专区首页| 国产精品一线二线三线有什么区别| 日韩一级一片内射文字幕高清| 扒开女人两片毛茸茸黑森林| 久久人人妻人人做人人爽| 亚洲黄片无码国产精品伊人av|